Overview
This guide covers the physical installation of KanexPro Controls products — processors, expanders, keypads, and touch panels. Complete hardware installation before network configuration or programming.
Control Processors
CR-HOST6S — Compact Processor
- Mount on an AV rack shelf, under-table surface, or in an AV closet. Allow at least 5cm clearance on all sides for ventilation.
- Connect RS-232 DB9 cables from the serial ports to each controlled device. Label each cable with the device name and port number.
- Connect IR emitter cables (3.5mm mono) to IR output ports. Route emitter leads to the IR receiver window of each controlled device.
- Wire relay outputs to the controlled load (projector screen, lighting relay, etc.) using appropriate gauge wire for the relay current rating.
- Connect Ethernet to the network switch for management and control traffic.
- Connect keypads or touch panels to the PoE output ports if not using a separate PoE switch.
- Connect the included power supply and power on.
CR-HOST8R — 1U Rack Processor
- Rack-mount in a standard 19-inch AV rack (1U). Secure with rack screws on both sides.
- Connect RS-232 and IR/Serial combo port cables to all controlled devices. All 8 combo ports are individually configurable as RS-232 or IR in the web GUI.
- Wire 8 relay outputs to controlled loads. Use terminal block connectors (included).
- Wire digital I/O ports to contact closure inputs (sensors, buttons) or logic-level outputs as required.
- Connect Ethernet to the network switch.
- Connect the included power supply.
Expanders
CR-EXPAND1 / CR-3XCONTROL (PoE)
- Mount near the devices being controlled (projector alcove, display wall, AV closet).
- Connect a PoE Ethernet cable from the switch to the device. PoE provides both power and network connectivity via a single cable.
- Connect RS-232, IR, relay, and digital I/O cables to local controlled devices.
- Configure the device IP in the processor script to link it as an I/O node.
CR-EXPAND4 (Rack/Surface)
- Rack-mount (1U) or surface-mount using included brackets.
- Connect 4 RS-232 cables to locally controlled devices.
- Connect Ethernet and the included power supply.
Keypads
- Run a single CAT5e/CAT6 Ethernet cable to the wall box at the desired keypad location before drywalling.
- Mount the keypad bracket into a US standard 1-gang (CR-KEY8U) or 2-gang (CR-KEY10R) wall box.
- Connect the Ethernet cable to the keypad’s RJ45 port. PoE from the switch powers the keypad.
- Snap the keypad face into the bracket.
- Insert custom button label inserts (CR-KEY8U, CR-KEY10R).
Touch Panels (CR-TOUCH4A / CR-TOUCH6R)
Both touch panels are designed for an 86×86mm wall box — the standard single-gang size used in the UK, Europe, China, and most international markets.
Installation in an 86×86mm Wall Box (UK / International)
- Run a CAT5e/CAT6 Ethernet cable to the wall box location before drywalling. Terminate with an RJ45 connector.
- Fit an 86×86mm back box (minimum 35mm depth recommended) into the wall at the desired location.
- Feed the Ethernet cable through the back box.
- Connect the Ethernet cable to the panel’s RJ45 port. PoE+ from the switch powers the panel — no separate power cable is required.
- Mount the panel bracket to the back box using the included screws.
- Snap or slide the panel face onto the bracket.
- Power on — the panel boots to the control interface after approximately 30 seconds.
Installation in a US Standard Wall Box
US single-gang electrical boxes (approx. 70×100mm device opening) are a different size from the 86×86mm panels. To install a KanexPro touch panel in a US wall box, an 86mm-to-US single-gang adapter plate is required.
- Purchase an 86mm-to-US decora adapter plate (available from AV accessory suppliers). This plate mounts into a standard US 1-gang electrical box and provides an 86×86mm opening for the panel.
- Run a CAT5e/CAT6 Ethernet cable to the US wall box location. Terminate with an RJ45 connector.
- Install the US wall box into the wall (old-work or new-work box as appropriate for the wall type).
- Attach the 86mm adapter plate to the US wall box using the box’s mounting screws.
- Feed the Ethernet cable through the adapter plate opening.
- Connect the Ethernet cable to the panel’s RJ45 port.
- Mount the panel bracket to the adapter plate using the included screws.
- Snap or slide the panel face onto the bracket.
- Power on — the panel boots after approximately 30 seconds.
Note: Confirm the adapter plate depth is compatible with your US wall box depth before purchase. Minimum recommended cavity depth behind the panel is 35mm.
For CR-TOUCH6R: RS-232/RS-485 Local Connection
If using the CR-TOUCH6R’s onboard RS-232/RS-485 port, route the serial cable through the wall box alongside the Ethernet cable before closing the wall. Connect to the local device after mounting.
Cable Summary
- RS-232: DB9 cable (straight-through for most AV devices; null modem if TX/RX must be crossed)
- IR: 3.5mm mono IR emitter cable
- Relay: 18–22 AWG wire, terminal block connection
- Network: CAT5e minimum, CAT6 recommended; standard RJ45